Abstract
Permanent magnet synchronous motors (PMSMs) are applied in high performance positioning and variable speed applications because of their enhanced features with respect to other AC motor types. Fault detection and diagnosis of electrical motors for critical applications is an active field of research. However, much research remains to be done in the field of PMSM demagnetization faults, especially when running under non-stationary conditions. This paper presents a time–frequency method specifically focused to detect and diagnose demagnetization faults in PMSMs running under non-stationary speed conditions, based on the Hilbert Huang transform. The effectiveness of the proposed method is proven by means of experimental results
چکیده
موتورهای سنکرون مغناطیس دائم (PMSMs) به دلیل دارا بودن ویژگی های پیشرفته تر نسبت به سایر موتورهای AC، در موقعیت یابی عملکرد بالا و کاربردهای سرعت متغیر به کار می روند. تشخیص خطا و عیب یابی موتورهای الکتریکی برای کاربردهای حساس، یک زمینه تحقیق فعال می باشد. البته، تحقیقات زیادی باقی مانده است که در زمینه خطاهای مغناطیس زدایی PMSM، به ویژه به هنگام راه اندازی تحت شرایط متغیر باید انجام شود. این مقاله، یک روش زمان – فرکانس با توجه ویژه به آشکار سازی و تشخیص خطاهای مغناطیس زدایی در راه اندازی PMSMها تحت شرایط سرعت متغیر مبتنی بر تبدیل هیلبرت هوآنگ ارائه می دهد. کارایی روش پیشنهادی توسط نتایج تجربی به اثبات رسیده اند.
1-مقدمه
صنعت به طور دائم خواستار محصولاتی است که سریع تر و قابل اطمینان تر هستند. در این زمینه، برای برخی زمینه های مهم، موتورهای سنکرون مغناطیس دائم (PMSMها) دارای ویژگی های بهتری نسبت به موتورهای القایی هستند. PMSMها به دلیل دارابودن ویژگی های جالب، به طور گسترده ای در موقعیت یابی عملکرد بالا و کاربردهای سرعت متغیر مورد استفاده قرار می گیرند...